dc.contributor.author |
Pimentel, Jussálvia da S. |
|
dc.contributor.author |
Silva, Tonny J. A. |
|
dc.contributor.author |
Borges Júnior, João C. F. |
|
dc.contributor.author |
Folegatti, Marcos V. |
|
dc.contributor.author |
Montenegro, Abelardo A. A. |
|
dc.date.accessioned |
2018-12-04T13:06:52Z |
|
dc.date.available |
2018-12-04T13:06:52Z |
|
dc.date.issued |
2010-02 |
|
dc.identifier.citation |
PIMENTEL, J. S. et al. Estimativa da transpiração em cafeeiros utilizando-se sensores de dissipação térmica. Revista Brasileira de Engenharia Agrícola e Ambiental, Campina Grande, v.14, n.2, p.187-195, 2010. |
pt_BR |
dc.identifier.issn |
1807-1929 |
|
dc.identifier.uri |
http://dx.doi.org/10.1590/S1415-43662010000200010 |
pt_BR |
dc.identifier.uri |
http://www.sbicafe.ufv.br/handle/123456789/10567 |
|
dc.description.abstract |
Alguns métodos são capazes de determinar diretamente a quantidade de água consumida por uma planta, entre eles o “método de dissipação de calor” ou método de Granier. Neste trabalho se propôs, como objetivo, construir e calibrar sensores de dissipação térmica, avaliar a transpiração em função da posição de inserção do sensor na planta (Norte, Sul, Leste ou Oeste) e comparar os resultados com os elementos meteorológicos e a evapotranspiração de referência. Em 24 cafeeiros se instalaram sensores de dissipação térmica, adaptados de Granier (1985), em que o conjunto termopar e resistência foi inserido na agulha. Obteve-se a densidade de fluxo de seiva a partir da variação da diferença de tempe- ratura entre as sondas e se acompanhou a transpiração, em função da transição entre os períodos diurno e noturno. O experimento foi avaliado em 3 períodos: antecedente à floração, na floração e no início da frutificação. Não houve dife- rença significativamente entre os ângulos de inserção para o fluxo de seiva. Quanto aos elementos meteorológicos, a radiação e a umidade relativa foram os fatores mais determinantes da transpiração obtendo-se, por análises de regressão coeficientes R 2 entre 0,84 e 0,80. |
pt_BR |
dc.description.abstract |
Some methods are capable of directly determining the amount of water consumed by a plant, among them, the “heat dissipation method” or Granier method. This study aimed to: build and calibrate sensors of thermal dissipation; to evaluate the transpiration as a function of the position of insertion of the sensor in the plant (North, South, East or West) and to compare the results with the meteorological elements and the evapotranspiration of reference. In 24 coffee plants, thermal dissipation sensors adapted from Granier (1985) were installed, where the whole thermocouple and resistance were inserted into the needle. Density of the sap flow was obtained from the variation of the difference in temperature between the probes and accompanied transpiration according to the transition between day and night periods. The experiment was evaluated during 3 periods: before flowering, during the flowering and at the beginning of fruiting. There was no significant difference between the angles of insertion to the sap flow. Regarding the meteorological elements, radiation and relative humidity were the most determinant factors in transpiration, obtained by analysis of regressions with, R 2 coefficients between 0.84 and 0.80. |
pt_BR |
dc.format |
pdf |
pt_BR |
dc.language.iso |
pt_BR |
pt_BR |
dc.publisher |
Departamento de Engenharia Agrícola - UFCG |
pt_BR |
dc.relation.ispartofseries |
Revista Brasileira de Engenharia Agrícola e Ambiental;v.14, n.2, p.187–195, 2010 |
|
dc.rights |
Open Access |
pt_BR |
dc.subject |
Coffea arabica |
pt_BR |
dc.subject |
Fluxo de seiva |
pt_BR |
dc.subject |
Irrigação |
pt_BR |
dc.subject |
Evapotranspiração |
pt_BR |
dc.subject.classification |
Cafeicultura::Cafeicultura irrigada |
pt_BR |
dc.title |
Estimativa da transpiração em cafeeiros utilizando-se sensores de dissipação térmica |
pt_BR |
dc.title |
Estimation of transpiration in coffee crop using heat dissipation sensors |
pt_BR |
dc.type |
Artigo |
pt_BR |